Currency AZN
AVR-01-K control device back supply buy in Baku
Buy AVR-01-K control device back supply
AVR-01-K control device back supply
ustrojstvo_upravleniya_avr_01_k_rezervnym_pitaniem

AVR-01-K control device back supply

In stock
Reconfirm the price with seller
Shipping:
Seller
Azerbaijan, Baku
(View map)
+994 
Display phones
Technical characteristics
  • TypeEmergency input of the reserve
Description

Assignment:

The control device of AVR-01-K is intended for creation of schemes AVR with two inputs of a power supply, one loading.

Principle of work:

The control device of AVR-01-K controls tension on two inputs of the three-phase alternating current main. If tension within norm, loading is connected to the main input by means of the external switch (the contactor, the time cut-out with the motor drive, etc.) which is managed by the AVR-01-K final-control relay. At accident loading is connected to reserve input of a power supply. At recovery of a power supply on the main input loading switches to it. A power supply of AVR-01-K is carried out from controlled inputs.

Specifications:

Parameter AVR-01-K
Type of controlled lines: 4-wire (3x400B+N)
Supply voltage: 85-264B
Number of controlled inputs: 2
Number of final-control relays: 3
Max. current of contacts of the relay: 16A AC1
Max. current of the coil of the contactor: 3A
Contacts: 3x1P (switching)
Shutdown tension threshold:
- lower
- upper

150-180B
240-270B
Clearing time:
- for a lower limit
- for an upper limit

5B
0,3B
Admissible asymmetry of tension: 60B
Time otkl. on asymmetry: 5 sec.
Switching time from the basic
on reserve input:
0,3-5sek
Time incl. the main of input at
voltage recovery:
5 sec. - 10 min.
Degree of protection: IP20
Operating temperature range: from-25 to +50 C
Dimensions: 105kh65kh90mm

FUNCTIONAL FEATURES:

1. Control of alternation of phases.

2. Forming of tension of an operational power supply.

3. Asymmetry control.

4. Forming of a signal of start of the generator.

5. Management of contactors and motor drives.

6. Control of position of contactors (motor drives).

7. Availability of entrances of an emergency shutdown of loading.

8. A possibility of work from the external power source.

9. Preservation of working capacity with the voltage range from 24 to 264B.

10. The combined adjustment of upper and lower thresholds of tension.