Currency AZN
Oktanometr Shatox SX-300 – Yugra Invest TOO | all.biz
Buy Oktanometr Shatox SX-300
Oktanometr Shatox SX-300

Oktanometr Shatox SX-300

In stock
Reconfirm the price with seller
Payment:
Shipping:
Seller
Kazakhstan, Pavlodar
(View map)
+7(7 
Display phones
6
6 years on Allbiz
Description

Description

The universal analyzer of quality of oil products is manufactured on the basis of the modern high - precision microprocessor. The device can be shared with the personal computer or the laptop by means of the USB interface. In the analyzer automatic computer calibration, preservation of results of measurement in memory with date and time of carrying out the analysis with their subsequent transfer to the computer is used (in the Microsoft Excel or txt format).
-

Distinctive feature of an oktanometr of SX - 300 is the additional sensor which with high precision measures the specific volume resistance of oil products. Therefore the analysis of fuel can happen in two sizes, it allows to measure gasoline octane number with ferriferous (ferrocene), nickel and manganese additives, and also to determine the content of other substances.

In addition using this principle of measurement the device allows to define:

  • content of mechanical impurity in oil products -
  • alkaline number of motor oils -
  • availability of metallic additives in gasoline -
  • specific volume resistance of oil products.

When determining the induction period of gasoline on the device the fuel brand is chosen. Depending on it the device switches to the corresponding operating mode. -

Identification of brand of engine oil happens by the principle of definition of dielectric permeability. Original engine oils have a certain size of this characteristic. Brands of oils of the leading producers are included into the database of the device (the database can be replenished or change). Percentage of water in oil and oil products is defined according to GOST 14203 - 69. This opportunity allows to use the device as a dielkometrichesky hydrometer for oil products.

In the analyzer the timer chip which allows to keep results of measurement with date and time of carrying out the analysis is used. Also these data can be transferred to the computer.

The new software for the computer is included in the package.

  • on the computer screen in a convenient form results of measurement are displayed -
  • the kept data are loaded from memory of the device into the computer -
  • automatic calibration will help to carry out quickly correction -

Technical characteristics:

  • Range of the measured octane numbers of gasolines from 40 to 135 - OCh
  • Limit of the allowed main error of measurement of octane numbers, no more than ±0.5 - OCh
  • Limit of the allowed value of a divergence between parallel measurements of octane numbers, no more than ±0.2 - OCh -
  • Range of determination of content of anti - detonation additives in gasolines 0.1 - 15 - % -
  • Limit of the allowed main error determination of content of anti - detonation additives in gasolines of 0.1% -
  • Range of measurement of the induction period of oxidation of gasoline 50 - 2400 - Min. -
  • Limit of the allowed main error of the induction period of oxidation of gasoline of 5%
  • The mode for definition of quality of gasoline on specific volume resistance 10 6 - 10 14 - Ohm -
  • Limit of the allowed main error on measurement of specific volume resistance of 3%
  • Range of measurement of cetane numbers 20 - 100 of TsCh
  • Limit blundered measurement of cetane numbers, no more than ±1.0 - TsCh
  • Limit of the allowed value of a divergence between parallel measurements of cetane numbers, no more than ± 0.5 - TsCh
  • Limit of temperature of hardening of diesel fuel blundered when determining ± 2 With
  • Range of determination of content of kerosene in diesel fuels of 0 - 95%
  • Limit of the allowed main error when determining content of kerosene in diesel fuels of 3%
  • Range of measurement of degree of purity (cleaning) of engine oils of 95 - 100%
  • Limit of the extent of purification of engine oils blundered measurement, no more than 0.1%
  • Limit of the allowed value of a divergence between parallel measurements of extent of purification of engine oils, no more than 0.01%
  • Range of measurement of dielectric permeability 1–5 - Unit fuel and lubricants.
  • Range of definition of alkaline number of oils 0 - 24 - ShchCh Unit -
  • Limit of the allowed main error when determining alkaline number of oils 1 - Unit -
  • Range of voltage measurement of breakdown of transformer oils (dielectrics) 5–100 - kV -
  • Range of determination of content mechanical impurity in oil products of 97 - 100%
  • Limit of the allowed main error when determining content mechanical impurity in oil products of 0.01%
  • Range of determination of content of water in oil products of 0 - 30%
  • Limit of the allowed main error when determining content of water in oil products of 1%
  • Measurement time 1–5 sec.
  • The term of operation of the device not less than 6 years -
  • Overall dimensions:
    • electronic block: mm 100х210х40
    • sensor No. 1 and No. 2, mm: mm 60х100
  • the mass of the device with two sensors 900gr

Ranges of measurement can change at the request of the customer!

The price is specified without the VAT!

$ ("table") . contents () . find ("a") of . attr ("rel") = "nofollow"

var google_tag_params = { ecomm_prodid: '1678', ecomm_pagetype: 'product', ecomm_totalvalue: 87900 } -

&nbsp
Contact the seller
Oktanometr Shatox SX-300
Oktanometr Shatox SX-300
Shipping method
Payment method
Compare0
ClearSelected items: 0