Описание

1 to 8 channels

Large LCD with real-time readings

3 LEDS quickly provide the status of the whole installation

Significant parking facility electricity savings

Up to 256 detectors

Multi-gas monitors up to 6 different gases: Carbon Monoxide Nitric Oxide Nitrogen Dioxide Methane Liquefied Petroleum Gas Hydrogen

Overview

Safe, Accurate and Reliable Car Park Air Monitor

The CPS car park air monitor accurately and reliably protects the public and employees from airborne toxic gases in parking facilities and tunnels. The system was designed to comply with the high air quality safety standards enforced in such European countries as Germany, the Netherlands and Belgium.

Optimizes Ventilation for Energy Savings

Continuous air monitoring significantly reduces your operating costs by optimizing the efficiency of ventilation systems and servo controls. Such efficiencies can produce energy savings of up to 40% when used with specific equipment.

Versatile and Programmable

Available in wall- and rack- mounted versions, the CPS™ central controller and its various modules are user-programmable for specific car park applications. The system's networking technology also enables the Car Park System™ to adapt to any installation up to:

  • 256 sensors capable of monitoring 6 different gases

  • 256 addressable relays

  • 64 logic inputs

  • 256 analog outputs.

Several servo controls can be used: low speed/high speed, delays, forced operation, night mode, etc.

Specification

CPS 10 Sensor Module

Dimensions:

Measured in mm:
118 x 110 x 60 (4.65′′ x 4.35′′ x 2.36′′)

Degree of protection:

IP 54

Cable glands:

2 M16 cable glands 4-8 mm diameter -
Power supply / local relays

Consumption:

Measured in mA:
2.5 for the toxic sensor (max 4-20)
50 explo: max 90.7

Status indication after calibration:

Red/green electroluminescent diode

Calibration:

Automatic, non-intrusive

Measuring ranges:

ppm in 1 ppm increments:
Carbon Monoxide - 0 to 300
Nitric Oxide - 0 to 100

Nitrogen Dioxide - 0 to 30 ppm in 0.1 ppm increments

LEL in 1% increments:
Methane - 0 to 100%
Liquefied Petroleum Gas - 0-100%
Hydrogen - 0 to 100%

Sensor replacement:

Sensor replacement switch on the interior of the CPS 10 case

CPS RM4 or RM8 Relay Module

Dimensions:

Measured in mm:
125 x 165 x 60 (4.92′′ x 6.5′′ x 2.36′′)

Number of relays:

4 relays (CPS RM4); 8 relays (CPS RM8) - Contacts: RCT-type

Contact rating:

2 A / 250 V

Consumption:

3.4 mA (max: 5.7 mA)

Connection:

Screwing Terminals (cable: 1.5 mm2)

Mounting:

On DIN rail

Configuration of positive or negative relay security with mini switches.
Relay modules are equipped with 2 all-or-nothing inputs.

CPS DI16 or Logic Input Module

Dimensions:

Measured in mm:
125 x 165 x 60 (4.92′′ x 6.5′′ x 2.36′′)

Number of all-or-nothing inputs:

16

Consumption:

3.2 mA (max: 5.5 mA)

CPS A04 Analog Output Module

Dimensions:

Measured in mm:
125 x 165 x 60 (4.92′′ x 6.5′′ x 2.36′′)

Number of analog outputs:

4

Consumption:

130 mA (max: 256 mA )

CPS™ Central Detection Controller

Wall-mount dimensions:

Measured in mm:
320 x 180 x 95 (12.6′′ x 7.09′′ x 3.74′′)

Degree of protection:

IP54

Cable Glands:

5 M20 cable glands - Diameter: 5 to 12 mm for power supply and local relays
9 grommets - Diameter: 5 to 7 mm or PG-9

Rack-mount dimensions:

Length: 19′′ - Height: 4 U (176 mm)

Degree of protection:

IP 31

Operating Conditions

Ambient temperature:

-10°C to +40°C

Storage temperature:

-20°C to +85°C

Humidity:

5 to 95% non-condensing

Main power supply:

Voltage: 85 to 264 VAC Current: 1.5 A (115 VAC) / 0.8 A (230 VAC)

Internal back-up battery:

Optional, 600 mA/h capacity

Consumption:

Measured in mA:
140 + 12 per measurement line (24 max.)

Measuring Lines

Capacity:

8 lines of 32 modules

Cable type:

2 shielded twisted pairs RS-485 cable

Module power supply:

12 to 30 VCC power supply delivered to modules via the central controller

Digital Module Network:

ModBus RS-485, 1-32 addresses selected with mini switches

Isolation:

1500 V between the power supply and the digital network

Display:

Backlit LCD display screen
(2 lines of 32 characters each - 1 line of pictograms)
3 operation status LEDs: OK, Fault, Alarms

Keyboard:

Intuitive 7-key

Local buzzer:

Audible alarm and fault signals

Integrated printer:

Optional for rack-mounted version

Alarms

Number of alarms:

6 per sensor (Out of range, AI4, AI3, AI3, AI1, Fault)

Programmable thresholds:

For instantaneous or averaged values, increasing or decreasing values, and manual or automatic rearming

3 local internal relays:

R1 (alarm/fault) - R2 (alarm) - R3 (alarm)

Minimum charge for RCT contacts:

2A/250 VAC-30 VCC (resistive charge)

Digital Outputs:

ModBus RS-485 protocol (connection with a centralized supervision device)
RS-232 or USB: USB protocol priority (permanent connection to system configuration)

Approvals

Low Voltage Directive:

This device is in compliance with the security requirements of Directive 73/23/EEC, modified by Directive 93/68/EEC, based on standard 61010-1 and its second amendment

Metrology:

Underground parking facilities: according to VDI 2053

EMC Electromagnetic compatibility:

According to EN 50270

Способы доставки
Связаться с продавцом
Fixed Gas Detection Controller Car Park System (CPS)
Fixed Gas Detection Controller Car Park System (CPS)
за
по товару
Ваше сообщение должно содержать не меньше 20 символов. Сообщение не может быть больше 2000 символов.
Не заполнено обязательное поле
Неверно заполнено поле
Неверно заполнено поле
Сравнить0
ОчиститьВыбрано позиций: 0