Русский
Валюта AZN
Fixed Gas Detection Controller WX 16 купить в Баку
Купить Fixed Gas Detection Controller WX 16
Fixed Gas Detection Controller WX 16

Fixed Gas Detection Controller WX 16

В наличии
Уточняйте цену у продавца
Пример: +994(50)123-45-67
Доставка:
Азербайджан, Баку
(Показать на карте)
+994 
Показать телефоны
5
5 лет на Allbiz
Описание
  • 16-channel controller

  • Analog and digital inputs

  • Programmable relays

  • RS-485 Modbus RTU Master/Slave

  • Wireless options

  • Graphical LCD display

  • Data logging (24 hrs)

  • Alarm strobe and horns optional

Overview

Reliable

The WX 16 controller is designed to offer maximum reliability and functionality.

  • Security mode allows for lockout of critical parameters

  • NEMA 4X/7 Enclosures

  • Non-volatile memory retains all configuration data

  • CSA Div 2 A,B,C,D and C22.2 No. 152 approved

Versatile

The WX 16 controller can be configured in multiple ways to meet your application needs. It offers analog, digital, and wireless capability and comes standard with four common alarm relays.

  • Accepts up to 16 4-20mA, bridge sensor, ModBus, or wireless channels

  • 4-20mA, ModBus RTU, wireless ModBus output

  • Four common SPDT relays standard

  • Optional discrete relays

  • Dual ModBus master/slave capability

Easy to Use

The WX 16 is designed to offer the user convenient features and ease of use.

  • Touch Key and Non-Intrusive (magnetic) Operation

  • Graphical Backlit LCD Display

  • Independent Alarm LEDs

  • Built-In Piezo Siren

Applications

  • Oil and Gas Industry

  • Offshore Drilling

  • Utilities and Power

  • Petrochemical Industry

  • Municipal Water and Waste Treatment

  • Food and Beverage Production

Wireless

Wireless communication is becoming increasingly popular in gas detection, and it is sometimes the only way to ensure safety in existing infrastructure or remote locations. The WX 16 can be configured to accept wireless inputs from an OLCT 200 transmitter, accept wireless ModBus inputs from a ModBus slave device, or communicate wirelessly to a compatible ModBus master device. Additionally, the WX 16's wireless option offers the following features:

  • 900MHz or 2.4GHz FHSS

  • 10mW - 1W Adjustable Tx Power

  • CSA Div 1 and DIV 2 Antennas

  • 256-bit Encryption

  • Dual Master/Slave Operation

  • Indoor Range up to 3000' (900 meters)

  • Outdoor Range up to 10 miles (16 km)

  • -100dBm Receiver Sensitivity

Specification

Display:

LCD (128 x 240 pixel) with backlighting

Indicators:

48 discrete LEDs for three alarm levels (Low, High, and Fault) for each of the 16 channels as well as 4 LEDs for common alarms and horn relays

Interface Buttons:

Five buttons - Dual Touch Key and Magnetic (Non-Intrusive)

Inputs:

• 16 channels (4-20mA, Bridge Sensor, ModBus, and Wireless)
• 4-20mA inputs are into 100 ohm impedance and include +power for each channel for routing power to 2-wire or 3-wire transmitters
• Bridge sensor inputs allow for adjustable sensor excitation and balance settings
• Up to 16 channels can be received wirelessly from an OLCT 200 transmitter configured with a wireless package or from a wireless ModBus slave

Outputs::

• Opt. 8/16-channel 4-20mA output (max load 800 ohms @24VDC)
• RS-485 ModBus RTU slave
• Wireless ModBus slave (900MHz or 2.4GHz)

Relays:

• Std. Four common, 5amp, 30VDC or 250VAC resistive Form C (2x-Alarm, 1x-Fault, 1x-Horn)
• Opt. Eight discrete, 5amp, 30VDC or 250VAC resistive Form C
• Additional discrete relays may be added in groups of eight
• Relays can be configured into up to 3 zones

ModBus:

Dual RS-485 ModBus RTU master/slave (9600 Baud)

Power supply:

Std. Accepts 10-30VDC; 12 watts max
Std. 100-240 VAC / 24VAC 150W

Wireless:

• 900MHz or 2.4GHz FHSS (Frequency Hopping Spread Spectrum)
• Single or Dual port radio modems allows for simultaneous transmit and receive
• 256-bit AES Encryption (meets FIPS-197)
• 10mW - 1W adjustable transmit power (900MHz), 120mW (2,4GHz)

Enclosure

Panel/Rack Mount:

5.22" (132 mm) H x 10.60" (269 mm) W x 9.60" (244 mm) D
Weight Approx. 7lbs. (3.2 kg)

Non-Metallic Wall Mount:

NEMA 4X
16.00" (406 mm) H x 13.16" (334 mm) W x 8.5" (216 mm) D
Weight Approx. 17lbs. (7.7 kg)

Stainless Steel Wall Mount:

NEMA 4X
20.70" (526 mm) H x 15.75" (400 mm) W x 8.0" (203 mm) D
Weight Approx. 30lbs. (13.6 kg)

Explosion-Proof Aluminum Wall Mount:

NEMA 4 / 7, for Div.1 & Div. 2 Groups B, C, D
22.38" (568 mm) H x 17.75" (451 mm) W x 9.06" (230 mm) D
Weight Approx. 110lbs. (49.9 kg)

Miscellaneous

Operating Temp:

-25°C to 60°C

Humidity:

0% - 90% Relative Humidity; Non-Condensing

Approvals:

CSA C22.2 No 152 for combustibles
CSA C22.2 No 1010.1 and ISA S82.02
UL 1604 / CSA C22.2 No 213 (Div 2 Groups A, B, C, D)
EN55011 and EN61000

Способы доставки
Связаться с продавцом
Fixed Gas Detection Controller WX 16
Fixed Gas Detection Controller WX 16
за
по товару
Ваше сообщение должно содержать не меньше 20 символов. Сообщение не может быть больше 2000 символов.
Не заполнено обязательное поле
Неверно заполнено поле
Неверно заполнено поле
Сравнить0
ОчиститьВыбрано позиций: 0